ChipFind - документация

Электронный компонент: LT280A

Скачать:  PDF   ZIP
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices
shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device spcification sheets before using any SHARP device.
Hall IC
s
Outline Dimensions
s
Operating Explanation
(Unit
:
mm
)
LT280A
*1 Soldering time : within 10 second
s
s
Absolute Maximum Ratings
(T
a
=25C)
Supply voltage
Output voltage
Output current
Power dissipation
Operating temperature
Storage temperature
Soldering temperature
*1
Symbol
V
CC
V
OUT
I
O
P
D
T
opr
T
stg
T
sol
Rating
6.5
6.5
5
100
-20 to +125
-55 to +150
260
Unit
V
V
mA
mW
C
C
C
Parameter
s
Electrical Characteristics
(T
a
=25C)
Operating magnetic flux density
Hysteresis breadth
Operating voltage
Supply current
Low level output voltage
Output leakage current
Operating point temperature drift
Symbol
B
OP
B
RP
B
H
V
CC
I
CC
V
OL
I
OH
B
OP
Condition
V
CC
=3V
V
OO
=3V
R
L
=4.7k
V
CC
=3V, B=<10mT
I
O
=4mA, B>=30mT
V
CC
=3V, V
OO
=3V, B=<10mT
V
CC
=3V, T
a
=-20C to +80C
MIN.
11.0
10.0
1.0
2.7
-
-
-
-
TYP.
-
-
-
-
3.5
-
-
2.5
MAX.
30.0
29.0
6.0
6.0
7.0
0.4
10
8.0
Unit
mT
mT
mT
V
mA
V
A
mT
Parameter
+
-
H
REG
Terminal connections
Hall
device
2.70.3
1.50.2
1
2
4
3
0.6
0.4
0.4
0.4
1.9
2.90.2
0.85
0.95
2.90.2
4-R0.2
S
Z
0.6
0.6
0.3
0.8
(0to0.15)
0.16
+0.10
-0.06
1.1
+0.2
-0.1
1 : V
CC
2 : V
OUT
3 : Don't use.
4 : GND
Y
X
Hall device center line
X : +0.050.23mm against package center
Y : -0.050.1mm against package lead center between
No.2 and No.3 terminals
Z : 0.810.15mm from package surface
*No.3 terminal and the section of lead (both sides
of package in X direction) are connected with the
terminal of internal IC. Be careful in connecting other circuits.
B
RP
0
B
OP
+B
Magnetic flux density
<Unidirectional magnetic field-type>
Output voltage
As for dimensions of tape-packaged products, refer to page 44 .
LT280A
GaAs Hall IC for Noncontact Switch
(Unidirectional magnetic field-type)
s
Applications
FDD
HDD
Water meter
Car stereo
Microswitch, etc.
s
Features
Suitable for portable equipment due to 3V operation
Operation by small magnet due to high sensitivity
Operating point<30mT
Combining a GaAs Hall device and an IC in a compact
package (2.9
X
1.5
X
1.1mm)
Wide operation temperature range obtained by GaAs Hall
device (-20 to +125C)
Long life time due to noncontact-type
Hall IC
LT280A
Fig. 1 Operating Magnetic Flux Density vs.
Supply Voltage
Fig. 3 Supply Current vs. Supply Voltage
Fig. 4 Supply Current vs. Ambient
Temperature
Fig. 5 Low Level Output Voltage vs.
Output Current
Fig. 6 Low Level Output Voltage vs.
Ambient Temperature
Fig. 2 Operating Magnetic Flux Density vs.
Ambient Temperature
V
CC
= V
B>=30mT
T
a
=25C
0
0
4
1
2
3
5
0.5
0.4
0.3
0.2
0.1
Low level output voltage V
OL
(V)
Output current I
O
(mA)
B=<10mT
T
a
=25C
0
0
8
2
4
6
10
10
8
6
4
2
Supply current I
CC
(mA)
Supply voltage V
CC
(V)
T
A
=25C
B
OP
B
RP
0
0
8
4
6
2
10
20
16
8
4
24
12
Operating magnetic flux density B
(mT)
Supply voltage V
CC
(V)
V
CC
=3V
B
OP
B
RP
0
80
0
40
-40
120
20
16
8
4
24
12
Operating magnetic flux density B
(mT)
Ambient temperature T
a
(C)
V
CC
=3V
B=<10mT
0
-40
120
0
40
80
10
8
6
4
2
Supply current I
CC
(mA)
Ambient temperature T
a
(C)
V
CC
=3V
I
O
=4mA
B>=30mT
0
80
-40
0
40
120
0.5
0.4
0.3
0.2
0.1
Low level output voltage V
OL
(V)
Ambient temperature T
a
(C)