ChipFind - документация

Электронный компонент: DN6852

Скачать:  PDF   ZIP
s Overview
The DN6852 is an integrated circuit making use of Hall
effects. It is designed particularly for operating at a low supply
voltage in one way magnetic field. It is suitable for various sen-
sors and contactless switches.
s Features
Wide range of supply voltage : 3.6 to 16V
Operating in one way magnetic field.
TTL and MOS ICs directly drivable by output
Semipermanent service life because of no contact parts
Drivable with a small magnet
3-pin SIL plastic package (3-SIP)
Open colector
s Applications
Speed sensors
Position sensors
Rotation sensors
Keyboard switches
Microswitches
Note) This IC is not suitable for car electrical equipments.
DN6852
Hall IC
(Operating Supply Voltage Range V
CC
=3.6 to 16V, Operating in One Way
Magnetic Field)
Unit : mm
SSIP003-P-0000A (E-3S)
1 : V
CC
2 : GND
3 : Output
0.5
0.1
5
1 2 3
2
5
5
2
1.27
4.0
0.3
0.7
4.5
0.3
0.43
+ 0.1
0.05
2.0
0.3
0.8
0.1
1.0
10.5
0.5
1
V
CC
Hall element
Amp.
Schmitt trigger
Output stage
3
Output
2
GND
Stabilized power supply
s Block Diagram
V
CC
I
CC
I
O
P
D
T
opr
T
stg
Supply voltage
Supply current
Circuit current
Power dissipation
Operating ambient temperature
Storage temperature
V
mA
mA
mW
C
C
Parameter
Symbol
Rating
Unit
s Absolute Maximum Ratings (Ta=25C)
18
8
20
100
40 to + 85
55 to + 125
Parameter
Symbol
Condition
min
typ
max
s Electrical Characteristics (Ta=25C)
Operating flux density
B
1 (L to H)
mT
V
CC
=12V
B
2 (H to L)
mT
V
CC
=12V
Low output voltage
V
OL
0.4
V
V
CC
=16V, I
O
=12mA,
B=60mT
V
V
CC
=3.6V, I
O
=12mA,
B=60mT
Note1) Operating supply voltage range V
CC
(opr)=3.6 to 16V
Note2) For the operating flux density, B
2 (H to L)
max 450 mT is also available as Rank A.
mA
V
CC
=16V
I
CC
mA
Supply current
V
CC
=3.6V
6
5.5
0.4
60
10
A
V
CC
=16V, V
O
=18V,
B=10mT
10
A
V
CC
=3.6V, V
O
=18V,
B=10mT
10
I
OH
High output current
Unit
1
.
3
1
.
0
1.75
1.0
Unit : mm
The center of the Hall element is in the hatched area in the left figure.
s Hall Element Position
Marking surface
1 : V
CC
2 : GND
3 : Output
Applied flux direction
N
S
1
2
3
Flux density (B)
O
u
t
p
u
t

v
o
l
t
a
g
e


(
V
O
)
B
1
B
2
s Flux-Voltage Conversion Characteristics
s Precaution on Use
1. Change of the operation magnetic flux density dose not depend on the supply voltage,
because the stabilization power supply is built-in.
(only for the range ; V
CC
=4.5 to 16V)
2. Change from "H" to "L" level increases the supply current by approx. 1mA.