ChipFind - документация

Электронный компонент: ARX5002

Скачать:  PDF   ZIP
Features
Low Noise, 20NV/Hz @10KHz, Typical
Full MilitaryTemperature Range, Built to MIlitary Standards
Full MilitaryTemperature Range, Built to MIlitary Standards
State of the Art Power Density, Smallest Possible Surface rea
Load Current Range up to 2 Amperes
Total Worst Case Line & Load Voltage Regulation, < +1%
Internal Short Circuit and Current Fold Back Protection
Available in Standard DC Voltages: +15V & +5V
Description
The ARX series of low noise DC
voltage regulators is a new line of ultra
highly reliable microcircuits designed for
military and aerospace applications.
These regulators utilize advanced
multichip module design techniques to
provide state-of-the-art performance
features with no sacrifice in reliability.
The ARX series regulators can be
used in applications where minimum size
and maximum output power is required.
These regulators are designed to operate
over the full military operating case
temperature range of -55C to +125C.
Outstanding high frequency ripple
rejection, input overshoot rejection and
input noise rejection are features of the
ARX series that are not available from
monolithic regulators.
To provide protection against output
overloads, current limiting and reduced
current foldback short circuit protection
are standard.
(Preliminary)
Aeroflex Laboratories Inc. 1995
PHYSICAL DIMENSIONS
1
3
0.030
0.105+/-.008
0.800 TYP
0.200 TYP
0.535
0.160 TYP.
0.345
0.820
0.118
0.690
0.040
0.260
0.070 TYP
(Actual Size)
2. Tolerances are +/-0.005 inches
Notes:
unless otherwise specified
1. Dimensions in inches
3. Package is a JEDEC standard
2
PIN #
FUNCTION
1
V
IN
2
V
OUT
3
GND
4. Case is electrically isolated
Features
Low Noise, 20NV/
@10KHz, Typical
Superior High Frequency Line Transient and Input Ripple Rejection
Full MilitaryTemperature Range, Built to MIlitary Standards
State of the Art Power Density, Smallest Possible Surface Area
Hz
REGULATORS
ARX LOW NOISE DC VOLTAGE
ARX5001 & ARX5002
CIRCUIT TECHNOLOGY
www.aeroflex.com
Multichip Modules For The Future
Table 1 Electrical Characteristics
Part Number
(Nominal Voltage)
ARX5002
( +15V )
ARX5001
( +5V )
Parameter
Conditions
(unless otherwise noted)
T
A
= -55C to +125C
Min
Nom
Max
Min
Nom
Max
Units
Input Voltage
Maximum load current
18
-
23
8
-
15
VDC
No load current
-
-
30
-
-
30
VDC
Output Voltage
Maximum load current
14.85
15.00
15.15
4.95
5.00
5.05
VDC
Load Current
Minimum Input voltage
-
-
1.8
-
-
1.8
ADC
Line Regulation
Delta input voltage = 3V
Maximum load current
-
20
50
-
1
10
mVDC
Load Regulation
Full load to no load current
-
-
100
-
35
50
mVDC
Short Circuit Trip Current
Minimum Input voltage
2
-
3.5
2
-
3.5
ADC
Short Circuit Foldback Current
Minimum Input voltage
0.10
0.20
0.40
0.10
0.20
0.30
ADC
Ripple Rejection
0 < f < 150kHz, I
L
= 900 mA
40
-
-
40
-
-
dB
Output Spot Noise
T
A
= + 25 C, V
IN
= minimum
10 kHz, I
L
= 900 mA
-
-
40
-
-
30
NV/ Hz
Notes
: 1. Maximum power dissipation is limited to 10 Watts at 125C case temperature
2. Custom voltage and short circuit trip current settings are available on special order
Circuit Technology
35 South Service Road
Plainview N.Y. 11803
Tele: (516) 694-6700
Fax: (516) 694-6715
Ordering Information
V
IN
V
out
ARX5001/
ARX5002
1
2
3
C
IN
C
OUT1
C
OUT2
Tantalum
5-10
F
Ceramic
0.1
F
Ceramic
1
F
GND
Recomended Wiring Diagram
ARX5001 +5 Volts
ARX5002 +15 Volts
6/23/95