eroflex Circuit Technology Voltage Regulator Modules For The Future ACT8600 REV A 9/16/99
COMMON FEATURES
I
Radiation 50K Total Dose
I
Output voltage adjustable
from 1.2V to 37V
I
1.5A output current
I
Current limit temperature
independent
I
Line regulation .01% typ
I
Output short circuit protected
I
Packaging Hermetic Metal
6 Leads, .65" x .42" x .200"
Power Package
I
Industrial , Military and Space
Temperature Range
I
DESC SMD TBD
POSITIVE FEATURES
I
Load regulation 0.1% typ
I
Ripple rejection 80dB typ
NEGATIVE FEATURES
I
Load regulation 0.3% typ
I
Ripple rejection 77dB typ
General Description
Aeroflex's ACT8600 is a radiation hardened, Dual adjustable 6-terminal device containing a
positive (LM117) and a negative (LM137) voltage regulator each capable of supplying in excess of
1.5A over an output voltage range of 1.2V to 37V. Each regulator is exceptionally easy to set-up,
requiring only 2 external resistors to set the output voltage. The module design has been optimized
for excellent regulation and low thermal transients. There is full electrical isolation between positive
and negative regulators and each to the package.
Further, the ACT8600 features internal current limiting, thermal shutdown and safe-area
compensation, making them virtually blowout-proof against overloads. The ACT8600 serves a
wide variety of applications including local on-card regulation, programmable output voltage
regulation or precision current regulation.
The ACT8600 has been specifically designed to meet exposure to radiation environments. It is
available in a 6 lead Metal Power Package. It is guaranteed operational from -55C to +125C.
Available screened to MIL-STD-883, the ACT8600 is ideal for demanding industrial, military and
space applications.
ACT8600
Rad Hard Dual Adjustable
Regulator
Positive & Negative Voltage
6
5
V
IN
ADJ
2
3
1
V
OUT
LM137
4
2
3
V
IN
ADJ
3
2
1
V
OUT
LM117
1
Block Diagram / Schematic
CIRCUIT TECHNOLOGY
www.aeroflex.com
F
I
E
I
D
C
E
R T
A
E
R
O
F
L E
X L A
B
S
I
N
C
.
ISO
9001
Aeroflex Circuit Technology
2
ACT8600 REV A 9/16/99 Plainview NY (516) 694-6700
Absolute Maximum Ratings
Parameter
Range
Units
Power Dissipation (P
D
)
20
W
Operating (Junction) Temperature Range
-55 to +150
C
Lead Temperature (soldering, 10 sec)
300
C
Storage Temperature Range
-65 to +150
C
Input-Output Voltage Differential
40
V
Thermal Resistance (junction to case
JC
)
5
C/W
ESD Rating
2
KV
NOTICE: Stresses above those listed under "Absolute Maximums Rating" may cause permanent damage to the device. These are stress
rating only; functional operation beyond the "Operation Conditions" is not recommended and extended exposure beyond the "Operation
Conditions" may effect device reliability.
Recommended Operating Conditions
Parameter
Range
Units
Output Voltage Range
Positive Voltage Regulator
Negative Voltage Regulator
1.2 to 37
-1.2 to -37
V dc
V dc
Ambient Operating Temperature Range
-55 to +125
C
Input Voltage Range
Positive Voltage Regulator
Negative Voltage Regulator
4.25 to 41.25
-4.25 to -41.25
V dc
V dc
Positive Regulator
Electrical Performance Characteristics
(T
A
= -55C to +125C, I
L
= 8mA, Unless otherwise specified)
Parameter
Sym
Conditions
Min
Max
Units
Reference Voltage
V
REF
V
DIF
= 3.0V, T
A
= + 25C
1.2
1.3
V
V
DIF
= 3.3V
1.2
1.3
V
V
DIF
= 40V
1.2
1.3
V
Line Regulation
R
LINE
3.0V < V
DIF
< 40V, V
OUT
= V
REF
, T
A
= + 25C
-
9
mV
3.3V < V
DIF
< 40V, V
OUT
= V
REF
-
23
mV
Load Regulation 1/
R
LOAD
V
DIF
= 3.0V, 10mA < I
L
< 1.5A, T
A
= + 25C
-
15
mV
V
DIF
= 3.3V, 10mA < I
L
< 1.5A
-
15
mV
V
DIF
= 40V, 10mA < I
L
< 300mA, T
A
= + 25C
-
15
mV
V
DIF
= 40V, 10mA < I
L
< 195mA
-
15
mV
Thermal Regulation
V
RTH
V
IN
= +14.6V, I
L
= 300mA, t = 20ms, P
D
= 20W,
T
A
= + 25C
-
16
mV
Ripple Rejection
R
N
f = 120Hz, C
ADJ
= 10F, V
OUT
= V
REF
2/
66
-
dB
Adjustment Pin Current
I
ADJ
V
DIF
= 3.0V, T
A
= + 25C
-
100
A
V
DIF
= 3.3V
-
100
A
V
DIF
= 40V
-
100
A
Adjustment Pin Current
Change
I
ADJ
V
DIF
= 3.0V, 10mA < I
L
< 1.5A, T
A
= + 25C
-
5
A
V
DIF
= 3.3V, 10mA < I
L
< 1.5A
-
5
A
V
DIF
= 40V, 10mA < I
L
< 300mA, T
A
= + 25C
-
5
A
V
DIF
= 40V, 10mA < I
L
< 195mA
-
5
A
Aeroflex Circuit Technology
3
ACT8600 REV A 9/16/99 Plainview NY (516) 694-6700
Adjustment Pin Current
Change con't
I
ADJ
3V < V
DIFF
< 40V, T
A
= + 25C
-
5
A
3.3V < V
DIFF
< 40V
-
5
A
Minimum Load Current
I
LMIN
V
DIF
= 3.0V, V
OUT
= 1.4 (forced), T
A
= + 25C
-
5
mA
V
DIF
= 3.3V, V
OUT
= 1.4 (forced)
-
5
mA
V
DIF
= 40V, V
OUT
= 1.4 (forced)
-
5
mA
Current Limit 2/
I
CL
V
DIF
= 15V
1.5
3.5
A
V
DIF
= 40V, T
A
= + 25C
0.18
1.5
A
Notes:
1/ Regulation is measured at a constant junction temperature, using pulse testing with a low duty cycle. Changes in output voltage due to heating
effects are covered under the specification for thermal regulation. With exception of cases U and 2, all output measurements are referenced
to the case. Measurements taken at the output lead must be adjusted for lead resistance.
2/ If not tested, shall be guaranteed to the specified limits.
Negative Regulator
Electrical Performance Characteristics
(T
A
= -55C to +125C, I
L
= 8mA, Unless otherwise specified)
Parameter
Sym
Conditions
Min
Max
Units
Reference Voltage
V
REF
V
DIF
= 3.0V, T
A
= + 25C
-1.275
-1.225
V
V
DIF
= 3.0V
-1.3
-1.2
V
V
DIF
= 40V, T
A
= + 25C
-1.275
-1.225
V
V
DIF
= 40V
-1.3
-1.2
V
Line Regulation
R
LINE
3.0V < V
DIF
< 40V, V
OUT
= V
REF
, T
A
= + 25C
-
9
mV
3.0V < V
DIF
< 40V, V
OUT
= V
REF
-
23
mV
Load Regulation 1/
R
LOAD
V
DIF
= 12V, 8mA < I
L
< 1.5A, T
A
= + 25C
-
25
mV
V
DIF
= 5V, 8mA < I
L
< 1.5A
-
25
mV
V
DIF
= 40V, 8mA < I
L
< 200mA, T
A
= + 25C
-
25
mV
V
DIF
= 40V, 8mA < I
L
< 100mA
-
25
mV
Thermal Regulation
V
RTH
V
IN
= -14.6V, I
L
= 1.5A, t = 10ms, P
D
= 20W,
T
A
= + 25C
-
5
mV
Ripple Rejection
R
N
f = 120Hz, C
ADJ
= 10F, V
OUT
= V
REF
2/
66
-
dB
Adjustment Pin Current
I
ADJ
V
DIF
= 3.0V
-
100
A
V
DIF
= 40V
-
100
A
Adjustment Pin Current
Change
I
ADJ
(Line)
3.0V < V
DIF
< 40V
-
5
A
I
ADJ
(Load)
V
DIF
= 5.0V, 8mA < I
L
< 1.5A
-
5
A
Minimum Load Current
I
LMIN
V
DIF
= 3.0V, V
OUT
= -1.4 (forced)
-
3
mA
V
DIF
= 10V, V
OUT
= 1.4 (forced)
-
3
mA
V
DIF
= 40V, V
OUT
= 1.4 (forced)
-
5
mA
Current Limit 2/
I
CL
V
DIF
= 5V
1.5
3.5
A
V
DIF
= 40V, T
A
= + 25C
0.24
1.2
A
Notes:
1/ Regulation is measured at a constant junction temperature, using pulse testing with a low duty cycle. Changes in output voltage due to heating
effects are covered under the specification for thermal regulation. With exception of cases U and 2, all output measurements are referenced
to the case. Measurements taken at the output lead must be adjusted for lead resistance.
2/ If not tested, shall be guaranteed to the specified limits.
Positive Regulator
Electrical Performance Characteristics (con't)
(T
A
= -55C to +125C, I
L
= 8mA, Unless otherwise specified)
Parameter
Sym
Conditions
Min
Max
Units
Aeroflex Circuit Technology
4
ACT8600 REV A 9/16/99 Plainview NY (516) 694-6700
.110
.200
.100
.118
.102
.407
.210
.420
.2035
R.020 TYP.
4 PLCS
.650
.420
.003
.200 MAX.
.005
.002
.030
.002
.040 DIA.
.109 .007
.150 REF.
2 MAX. TYP.
.020
.720
MEASURED
.LEAD TIP
IDENT
ESD/PIN 1
B
A
C
.010 B C A
M
.010
C B A
NOTE: 1. Dimension Tolerance: .005 inches
Package Outline -- Power Package
Aeroflex Circuit Technology
5
ACT8600 REV A 9/16/99 Plainview NY (516) 694-6700
C I R C U I T T E C H N O L O G Y
Aeroflex Circuit Technology
35 South Service Road
Plainview New York 11803
Telephone: (516) 694-6700
FAX: (516) 694-6715
Toll Free Inquiries: (800) THE-1553
Specifications subject to change without notice
www.aeroflex.com/act1.htm
E-Mail: sales-act@aeroflex.com
Ordering Information
Model Number
Screening
DESC SMD #
Package
ACT8600
Military Temperature, -55C to +125C,
Screened to the individual test methods
of MIL-STD-883
-
6 Lead Power Pkg